Individual engineering solution based on biotechnology and innovative approach to cleaning.



| Time | Cost | Harmless to materials | Does not require special recycling | Ecological | Forms a protective film | Rate of cleaning |
|---|---|---|---|---|---|---|
|
|
|
100% |
||||
| Overhaul | ||||||
|
|
|
98% |
||||
| Biotechnological cleaning | ||||||
|
|
|
90% |
||||
Mechanical cleaning |
||||||
|
|
|
80% |
||||
| Chemical cleaning | ||||||
|
|
|
75% |
||||
| Electro-physical cleaning | ||||||
|
|
|
1% |
||||
| Washing with water | ||||||
The results from the application of the “Organic cleaning” method are identical with those accomplished by a full repair, but this method is much cheaper and takes a much shorter time. After the cleaning the equipment regains its characteristics per specifications, the efficiency of the boilers and the machines is increased, energy is saved and the production losses decrease as a result of that.
At usage in the heat-supply, after the cleaning of the heating mains and the radiators, the admission capacity of the systems is restored and the temperature in the radiators is increased, as no harm is done to the metal or the rubber gaskets.
It is important to know, that after the cleaning with the products, offered by “Organic cleaning”, a protective layer is formed on the walls of the cleaned mains and equipment, which prevents the collection of slag and other organic precipitations, as well as protects the metals from corrosion. Last but not least the method is ecologically clean – no environmentally aggressive chemicals are used, as well as no carbon dioxide is emitted.
"Organic cleaning" is a new company, specialized in the field of biotechnological cleaning.
The company offers its customers a new type of service for ecological cleaning of mains for the supply of warm and cold liquids, boilers, drains, reservoirs, etc., based on an innovative method. The product which is used is developed on grounds of microbiological cultures. They produce complex organic acids, which decompose all types of furs and other organic accumulations, as well as the results of corrosion and different types of precipitation, obtained as a result of industrial activity. These acids are not aggressive towards the metals, plastics and the rubber gaskets. No dismantling of the equipment is necessary.
The company has the necessary equipment and high-qualified personnel, who perform the full cycle of activities, connected with the cleaning of the respective equipment.
...The biotechnology of cleaning the heat exchanger equipment by BiZ-1, BONAKA trademark, has proved its effectiveness, high degree of sediment removal, passivity with respect to brass pipes and other materials with which contact existed, as well as the possibility of draining into the general water disposal system. Separately, we note that BiZ-1 biocomposition has not had any harmful impact on either human health or the environment, which confirms its environmental safety. Having in mind the positive experience of using BiZ-1 biotechnology on peak boilers, it was planned to use it further for cleaning heat exchanging equipment at Krasnodar Heat Power Plant of LUKOIL-Kubanenergo LLC....
V.V.Voronyak - Deputy Chief Engineer of LUKOIL-Kubanenergo
...Inspection showed that on the return water section (black pipeline), through which the solution was circulating, there are no deposits on the entire internal surface. The internal surface of the pipeline was clean and with dull metallic color. The inlet distribution manifold (the distributor of circulating water on the plates, the plates are stainless) was perfectly clean with silvery color. As a result of cleaning more than 15 kg of a grit was extracted from the heat exchanger. The experimental washing carried out showed a high efficiency of cleaning the plates of heat exchanger from the deposits of circulating water. We propose during stop repair of shop 2A to flush the plate heat exchanger, position E-603 and the inter-tube part of the inter-stage cooler position K102/3. Also washing of inter-stage refrigerators on compressors in shop #2 should be carried out....
A.G.Lekomtsev - Director of Altek LLC (Branch of APK Bashneft OPLC, Bashneft-UNPZ)
...According to the results of the cleaning of the heat exchanger, a positive result, significantly better than the acidic wash, was reported. We consider the proposed technology for cleaning the heat exchange equipment is appropriate for use....
I.G. Tourutilna - Deputy Head of PTO, Nadim Branch of Gazprom Energo OAO
...The deposits inside the tubes and on the heater covers were completely dissolved, which increased the heat transfer by 20-30%.. The technology using Bioorganic Composition (BIZ-1) TU 2634-001-36628895-10 Bonaca brand is recommended for cleaning of heating equipment and pipes in the boiler farm, because it is effective, environmentally friendly, safe and economically profitable....
G.V.Bukin - Head of DTVu - 6, Central Directorate for Heat and Water Supply - branch of Russian Railways OJSC
...As a result of the cleaning, the pressure drop at the inlet and outlet of the heat exchanger equipment has significantly decreased the difference in temperatures at the inlet and outlet has returned to the passport values, both on the external circuit for heat consumers and on the internal circuit from the side of the boiler equipment....
A.A.Lykov - Director of AF of Teploenergoservis JSC
...Before cleaning, the inlet temperature (1 circuit/2 circuit) was 54/40 degrees, after cleaning, the temperature increased by 14 and 4 degrees, respectively, and the outlet temperature also increased. After cleaning, the pressure decreased noticeably (by 0.2 - 0.4 Bar), the water permeability increased. Thanks to high-quality work with the use of new technologies, it became warmer in our 5-storey office building!...
O.Y.Kiek - Director of ARMADA LLC
...The effectiveness of the work performed meets the requirements established by the contract. The purification level was 99%. The heat dissipation of equipment was increased by 25%. The results were given in a report. Taking into account the technological efficiency, the cleanliness of cleaning from the slurry and the scale of the reaction equipment on the basis of the BiZ-1 reagent (strain No. 18), by decision of the technical council of Krastsvetmet JSC this method was recommended for use...
A.Riabichkov - Development Director, Krastsvetmet LLC
...In July 2014, works were carried out to flush the heating system of the building of the GKKB No named after P.I. Pichugin (Perm). The heating system is single-pipe, the distributing and supply pipelines are made of a gas- and water conducting metal pipe, the radiators are cast-iron. The heating system is brought into a normal (nominal) working state and there is no need for a major overhaul (replacement) of the heating system, which allowed to save about 948,264.52 rubles of budget funds and to create comfortable conditions for patients and the work of staff. The coefficient of heat transfer efficiency of the system has increased 2.61 times. ...
City Children's Clinical Hospital № 9 named after P.I. Pichugin, Perm
At necessity of residential or industrial equipment cleaning with the BONAKA technology, do not hesitate to contact our professional advice experts: